- Check physical cable dressing:
One of the quick task for you to check the cable dressing and connectivity cables inside Storage. You will notice that poor dressing may cause obstruction for Hot air flow from rear side of the storage can result in high temperature and noise. - Check Storage LED indicator:
Check if any disk is showing amber light showing the faulty state and require replacement. - Check check room temperature:
Another obvious check is to check the room temperature. It should be between 18-2o°c. - Check events log:
Check if there is any log in Events – StoreWize3700 > Monitoring > Events - Reset Canister and Enclosure: (Finally, this step worked for me)
If none of above steps worked for you then run below commands in storage console and observe storage status. Connect via ssh to the storage.default login user: superuser
default password: passw0rdchenclosurecanister -reset -canister <Canister ID> <Enclosure ID>example:
if canister 1chenclosurecanister -reset -canister 1 2
if canister 2
chenclosurecanister -reset -canister 2 2
Note : 1) This command activity will not require any downtime if storage is in optimal state at hardware front.
2) The fan will go 120% for 30 seconds and then will drop to normal levels.